Gulfstream V Systems Review
OXYGEN
- How can you tell if the oxygen cylinder manual shutoff knob has been turned off?
- Pressure switch between the tank regulator and check valve monitors pressure in the supply line and will display an amber "crew oxygen off" or a "pax oxygen off" CAS message
- Overboard discharge will occur when regulated oxygen pressure exceeds _________ PSI, Cylinder pressure exceeds ____________ PSI, or oxygen temperature exceeds __________F.
- 90 PSI, 2600 PSI, 225 Degrees
- True or false: A passenger breathing oxygen will not deplete the crewmembers supply.
- False: The two supply cylinders join on a common supply line to all occupants.
- Crew and passengers masks are not approved for use above ________ feet.
- 40,000
- Passenger masks will not provide sufficient oxygen for prolonged operation above ________________ feet cabin altitude. Prolonged operation above ________________ feet cabin altitude with passengers aboard is not recommended.
- 34,000, 25,000
- In the auto position the passenger masks will automatically deploy when sensed cabin altitude reaches ________________ feet.
- 13,000
PNEUMATICS
- The first set point regulates high stage pressure from ____ to ____ psi for descent, holding, or vmin operation to provide adequate air flow at low power settings.
- 14 to 22 PSI
- A high stage regulation set point is also available to increase airflow during single pack operations. during single pack ops, it is reset to ___ PSI. If mid stage pressure falls below __PSI, the high stage bleed valve will open and regulate at __PSI.
- 35, 35, 35
- THe final possibility for high stage regulation occurs when wing a/i is on. if the temp is less than ____F at the precooler inlet, the controller will command opening of the the high stage bleed valve to achieve ____ F.
- 620 F, 620 F
- If a single manifold pressure valve or a single wing a/i valve is on, bleed air is cooled to maintain a maximum of ____ F degrees at the precooler outlet sensor.
- 500 F
- The ___________________ monitors precooler outlet temperature and modulates the opening of the fan air valve as required.
- Bleed air controller
- The high stage bleed air valve is controlled by the ______________.
- Bleed air controller
- True or false: As long as the fifth stage bleed air supply meets air pressure demands the high stage bleed air valve will remain closed.
- True
This article is included in Gulfstream Contract Pilot Services' resource library strictly for your convenience. The information in this article is provided without guarantee or warranty, and is subject to change without notice. The information is the opinion of the writer, and may not reflect the opinion(s) of Gulfstream Contract Pilot Services or it's associates. The information should not be relied upon as advice to help you with your specific issue. We recommend that you discuss the specific facts of your situation with a qualified professional before making any personal or business decisions.